5产品分类
5.1产品按连接方式不同分为弹性密封圈式和溶剂粘接式。
5.2公称压力等级和规格尺寸见表2和表3。
表2 公称压力等级和规格尺寸
单位为毫米
|
公称 外径 dn |
管材S系列SDR系列和公称压力 | ||||||
| S16 | S12.5 | S1O | S8 | S6.3 | S5 | S4 | |
| SDR33 | SDR26 | SDR21 | SDR17 | SDR13. 6 | SDR11 | SDR9 | |
| PN0. 63 | PN0. 8 | PN1.0 | PN1.25 | PN1.6 | PN2.0 | PN2.5 | |
| 公称壁厚en | |||||||
| 20 | — | — | — | — | 2.0 | 2.3 | |
| 25 | — | — | — | — | 2.0 | 2.3 | 2.8 |
| 32 | — | — | — | 2. 0 | 2.4 | 2.9 | 3. 6 |
| 40 | — | — | 2.0 | 2.4 | 3.0 | 3.7 | 4.5 |
| 50 | — | 2.0 | 2.4 | 3.0 | 3.7 | 4.6 | 5.6 |
| 63 | 2.0 | 2.5 | 3.0 | 3,8 | 4.7 | 5.8 | 7. 1 |
| 75 | 2.3 | 2.9 | 3.6 | 4.5 | 5.6 | 6.9 | 8.4 |
| 90 | 2.8 | 3.5 | 4.3 | 5.4 | 6.7 | 8.2 | 10. 1 |
| 注:公称壁厚(en)根据设计应力(σs)10 MPa确定,*小壁厚不小于2.0 mm. | |||||||
|
公称外径 dn |
管材S系列SDR系列和公称压力 | ||||||
|
S20 SDR41 PN0. 63 |
S16 SDR33 PN0.8 |
S12.5 SDR26 PN1.0 |
S10 SDR21 PN1.25 |
S8 SDR17 PN1.6 |
S6. 3 SDR13.6 PN2.0 |
S5 SDR11 PN2.5 |
|
| 公称壁厚en | |||||||
| 110 | 2.7 | 3.4 | 4.2 | 5.3 | 6.6 | 8.1 | 10.0 |
| 125 | 3. 1 | 3.9 | 4.8 | 6.0 | 7.4 | 9.2 | 11.4 |
| 140 | 3.5 | 4.3 | 5.4 | 6.7 | 8.3 | 10.3 | 12.7 |
| 160 | 4.0 | 4.9 | 6.2 | 7.7 | 9.5 | 11.8 | 14. 6 |
| 180 | 4.4 | 5.5 | 6.9 | 8.6 | 10.7 | 13.3 | 16.4 |
| 200 | 4.9 | 6.2 | 7.7 | 9.6 | 11.9 | 14.7 | 18.2 |
| 225 | 5.5 | 6.9 | 8.6 | 10.8 | 13.4 | 16.6 | — |
| 250 | 6.2 | 7.7 | 9.6 | 11.9 | 14. 8 | 18.4 | — |
| 280 | 6.9 | 8.6 | 10.7 | 13.4 | 16.6 | 20.6 | — |
| 315 | 7.7 | 9.7 | 12.1 | 15.0 | 18.7 | 23.2 | — |
| 355 | 8.7 | 10.9 | 13.6 | 16.9 | 21.1 | 26.1 | — |
| 400 | 9.8 | 12.3 | 15.3 | 19.1 | 23.7 | 29.4 | — |
| 450 | 11.0 | 13.8 | 17.2 | 21.5 | 26.7 | 33.1 | — |
| 500 | 12.3 | 15.3 | 19. 1 | 23.9 | 29.7 | 36.8 | — |
| 560 | 13.7 | 17.2 | 21.4 | 26.7 | — | — | — |
| 630 | 15.4 | 19.3 | 24.1 | 30.0 | — | — | — |
| 710 | 17.4 | 21.8 | 27.2 | — | — | — | — |
| 800 | 19.6 | 24.5 | 30. 6 | — | — | — | — |
| 900 | 22.0 | 27.6 | — | — | — | — | — |
| 1 000 | 24.5 | 30.6 | — | — | — | — | — |
| 注:公称壁厚(en)根据设计应力(σs)12.5 MPa确定 | |||||||
6.1外观
管材内外表面应光滑,无明显划痕、凹陷、可见杂质和其他影响达到本部分要求的表面缺陷.管材端面应切割平整并与轴线垂直。
6.2颜色
管材颜色由供需双方协商确定,色泽应均匀一致。
6.3不透光性
管材应不透光。
6.4管材尺寸
6.4.1长度
管材长度一般为4 m、6 m,也可由供需双方协商确定。管材长度(L)、有效长度(L1)见图1所示。长度不允许负偏差。
6.4.2弯曲度
管材弯曲度应符合表4规定。 表4管材弯曲度
| 公称外径dn/mm | ≤32 | 40 〜200 | ≥225 |
| 弯曲度/(%) | 不规定 | ≤1.0 | ≤0.5 |
平均外径及偏差和不圆度应符合表5规定,PN0.63、PN0.8的管材不要求不圆度。不圆度的测量应在出厂前进行。
表5 平均外径及偏差和不圆度 单位为毫米
| 平均外径dem | 不圆度 | 平均外径dem | 不圆度 | ||
| 公称外径dn | 允许偏差 | 公称外径dn | 允许偏差 | ||
| 20 |
+ 0.3 0 |
1.2 | 225 |
+0.7 0 |
4.5 |
| 25 |
+ 0.3 0 |
1.2 | 250 |
+0.8 0 |
5.0 |
| 32 |
+0.3 0 |
1.3 | 280 |
+0.9 0 |
6.8 |
| 40 |
+0.3 0 |
1.4 | 315 |
+1.0 0 |
7.6 |
| 50 |
+0.3 0 |
1.4 | 355 |
+ 1.1 0 |
8.6 |
| 63 |
+0.3 0 |
1.5 | 400 |
+ 1.2 0 |
9.6 |
| 75 |
+0.3 0 |
1.6 | 450 |
+ 1.4 0 |
10.8 |
| 90 |
+ 0.3 0 |
1.8 | 500 |
+ 1.5 0 |
12.0 |
| 110 |
+0.4 0 |
2.2 | 560 |
+ 1.7 0 |
13.5 |
| 125 |
+0.4 0 |
2.5 | 630 |
+ 1.9 0 |
15.2 |
| 140 |
+ 0.5 0 |
2.8 | 710 |
+ 2.0 0 |
17.1 |
| 160 |
+0.5 0 |
3.2 | 800 |
+ 2.0 0 |
19.2 |
| 180 |
+0.6 0 |
3.6 | 900 |
+ 2.0 0 |
21.6 |
| 200 |
+0.6 0 |
4.0 | 1 000 |
+ 2.0 0 |
24.0 |
6.4.4壁厚
6.4.4.1管材任意点壁厚及偏差应符合表2、表3和表6的规定。 表6 壁厚及偏差 单位为毫米
| 壁厚ey | 允许偏差 | 壁厚ey | 允许偏差 |
|
e≤2.0 |
+ 0.4 0 |
20. 6﹤e≤21.3 |
+ 3.2 0 |
|
2.0﹤e≤3. 0 |
+ 0.5 0 |
21.3﹤e≤22.0 |
+ 3.3 0 |
|
3.0﹤e≤4. 0 |
+ 0.6 0 |
22.0﹤e≤22.6 |
+ 3.4 0 |
|
4.0﹤e≤4. 6 |
+ 0.7 0 |
22.6﹤e≤23. 3 |
+ 3.5 0 |
|
4.6﹤e≤5.3 |
+0.8 0 |
23.3﹤e≤24. 0 |
+ 3.6 0 |
|
5.3﹤e≤6. 0 |
+ 0.9 0 |
24.0﹤e≤24.6 |
4-3.7 0 |
|
6.0﹤e≤6. 6 |
+ 1.0 0 |
24. 6﹤e≤25. 3 |
+ 3.8 0 |
|
6.6﹤e≤7.3 |
+ 1.1 0 |
25. 3﹤e≤26.0 |
+ 3.9 0 |
|
7.3﹤e≤8.0 |
+ 1.2 0 |
26. 0﹤e≤26. 6 |
+ 4.0 0 |
|
8.0﹤e≤8. 6 |
+ 1.3 0 |
26.6﹤e≤7. 3 |
+ 4.1 0 |
|
8.6﹤e≤9.3 |
+1.4 0 |
27.3 ﹤e≤28. 0 |
+ 4.2 0 |
|
9.3﹤e≤10.0 |
+ 1.5 0 |
28.0﹤e≤28.6 |
+ 4.3 0 |
|
10.0﹤e≤10. 6 |
+ 1.6 0 |
28.6﹤e≤29.3 |
+ 4. 4 0 |
|
10.6﹤e≤11.3 |
+ 1.7 0 |
29.3﹤e≤30.0 |
+ 4.5 0 |
| 11.3﹤e≤12.0 |
+ 1.8 0 |
30.0﹤e≤30.6 |
+4.6 0 |
|
12.0﹤e≤12.6 |
+ 1.9 0 |
30.6﹤e≤31.3 |
+4.7 0 |
|
12.6﹤e≤13.3 |
+ 2.0 0 |
31.3﹤e≤32.0 |
+ 4.8 0 |
|
13.3﹤e≤14.0 |
+ 2.1 0 |
32.0﹤e≤32.6 |
+4.9 0 |
|
14.0﹤e≤14. 6 |
+ 2.2 0 |
32. 6 ﹤e≤33. 3 |
+ 5.0 0 |
|
14.6﹤e≤5.3 |
+ 2.3 0 |
33. 3﹤e≤34.0 |
+ 5.1 0 |
|
15.3﹤e≤16.0 |
+ 2.4 0 |
34.0﹤e≤34.6 |
+ 5.2 0 |
|
16.0﹤e≤16. 6 |
+2.5 0 |
34. 6﹤e≤35.3 |
+ 5.3 0 |
|
16.6﹤e≤17.3 |
+ 2.6 0 |
35.3﹤e≤36.0 |
+ 5.4 0 |
|
17.3﹤e≤8.0 |
+ 2.7 0 |
36.0﹤e≤36.6 |
+ 5.5 0 |
|
18.0﹤e≤18.6 |
+ 2.8 0 |
36.6 ﹤e≤37.3 |
+ 5.6 0 |
|
19.6﹤e≤19.3 |
+ 2.9 0 |
37.3﹤e≤38.0 |
+ 5.7 0 |
|
19.3﹤e≤20.0 |
+ 3.0 0 |
38.0﹤e≤38.6 |
+ 5.8 0 |
|
20. 0﹤e≤20. 6 |
+ 3. 1 0 |
— | — |
| 平均壁厚em | 允许偏差 | 平均壁厚em | 允许偏差 |
| ≤2.0 |
+0.4 0 |
20.0﹤e≤21.0 |
+ 2.3 0 |
| 2.0 ﹤e≤3. 0 |
+0.5 0 |
21.0﹤e≤22.0 |
+ 2.4 0 |
| 3.0﹤e≤4.0 |
+0.6 0 |
22.0﹤e≤23.0 |
+ 2.5 0 |
| 4.0﹤e≤5.0 |
+ 0.7 0 |
23.0﹤e≤24.0 |
+ 2.6 0 |
| 5.0﹤e≤6. 0 |
+ 0.8 0 |
24.0﹤e≤25.0 |
+ 2.7 0 |
| 6. 0﹤e≤7. 0 |
+ 0.9 0 |
25.0﹤e≤26.0 |
+ 2.8 0 |
| 7.0﹤e≤8.0 |
+ 1.0 0 |
26. 0 ﹤e≤7. 0 |
+ 2.9 0 |
| 8.0﹤e≤9.0 |
+1.1 0 |
27. 0﹤e≤28. 0 |
+ 3.0 0 |
| 9.0﹤e≤10.0 |
+ 1.2 0 |
28.0﹤e≤29.0 |
+ 3.1 0 |
| 10.0﹤e≤11.0 |
+ 1.3 0 |
29. 0﹤e≤30.0 |
+ 3.2 0 |
| 11.0﹤e≤12.0 |
+ 1.4 0 |
30. 0﹤e≤31.0 |
+ 3.3 0 |
| 12.0﹤e≤13.0 |
1.5 0 |
31.0﹤e≤32.0 |
+ 3.4 0 |
| 13.0﹤e≤14.0 |
+ 1.6 0 |
32.0﹤e≤33. 0 |
+3.5 0 |
| 14.0﹤e≤15.0 |
+ 1.7 0 |
33.0﹤e≤34.0 |
+3.6 0 |
| 15.0﹤e≤16.0 |
+ 1.8 0 |
34. 0﹤e≤35. 0 |
+ 3.7 0 |
| 16.0﹤e≤17.0 |
+ 1.9 0 |
35.0﹤e≤36.0 |
+ 3.8 0 |
|
17.0﹤e≤8.0 |
+ 2.0 0 |
36.0﹤e≤37.0 |
+ 3.9 0 |
|
18.0﹤e≤19.0 |
+ 2.1 0 |
37.0﹤e≤38.0 |
+ 4.0 0 |
|
19.0﹤e≤20.0 |
+ 2.2 0 |
38.0﹤e≤39.0 |
+4.1 0 |
弹性密封圈式承口的密封环槽处的壁厚应不小于相连管材公称壁厚的0.8倍。
溶剂粘接式承口的*小深度、承口中部内径尺寸应符合表8规定,示意图见图3。
溶剂粘接式承口壁厚应不小于相连管材公称壁厚的0.75倍。
表8 弹性密封圈式承口*小深度
| 公称外径dn |
弹性密封圈承口*小配合深度 mmin |
溶剂粘接承口 *小深度 mmin |
溶剂粘接承口中部平均内径dsm | |
| dsm,min | dsm,max | |||
| 20 | — | 16.0 | 20.1 | 20.3 |
| 25 | — | 18.5 | 25.1 | 25.3 |
| 32 | — | 22.0 | 32.1 | 32.3 |
| 40 | — | 26.0 | 40.1 | 40.3 |
| 50 | — | 31.0 | 50.1 | 50.3 |
| 63 | 64 | 37.5 | 63.1 | 63.3 |
| 75 | 67 | 43.5 | 75.1 | 75.3 |
| 90 | 70 | 51.0 | 90.1 | 90.3 |
| 110 | 75 | 61.0 | 110.1 | 110.4 |
| 125 | 78 | 68.5 | 125.1 | 125.4 |
| 140 | 81 | 76.0 | 140.2 | 140.5 |
| 160 | 86 | 86.0 | 160.2 | 160.5 |
| 180 | 90 | 96.0 | 180.3 | 180.6 |
| 200 | 94 | 106.0 | 200.3 | 200.6 |
| 225 | 100 | 118.5 | 225.3 | 225.6 |
| 250 | 105 | — | — | — |
| 280 | 112 | — | — | — |
| 315 | 118 | — | — | — |
| 355 | 124 | — | — | — |
| 400 | 130 | — | — | — |
| 450 | 138 | — | — | — |
| 500 | 145 | — | — | — |
| 560 | 154 | — | — | — |
| 630 | 165 | — | — | — |
| 710 | 177 | — | — | — |
| 800 | 190 | — | — | — |
| 1000 | 220 | — | — | — |
|
注1:承口中部的平均内径是指在承口深度二分之一处所测定的相互垂直的两直径的算术平均值。 承口的*大锥度(a)不超过0°30′。 注2:当管材长度大于12 m时,密封圏式承口深度mmin需另行设计。 |
||||
6.5物理性能
物理性能应符合表9规定。 表9物理性能
| 项 目 | 技术指标 | 试验方法 |
| 密度 /(kg/m3) | 1350—1460 | 见7.5 |
| 维卡软化温度/℃ | ≥280 | 见7.6 |
| 纵向回缩率/(%) | ≤5 | 见7.7 |
| 二氯甲烷浸渍试验(15℃,15 min) | 表面变化不劣于4N | 见7.8 |
6.6力学性能
力学性能应符合表10规定。 表10力学性能
| 项 目 | 技术指标 | 试验方法 |
|
落锤冲击试验(0℃) TIR/(%) 液压试验 |
≤ 5 无破裂,无渗漏 |
见7.9 见7.10 |
管材与管材,管材与管件连接后应按表11要求做系统适用性试验。 表11系统适用性试验
| 项 目 | 要 求 | 试验方法 |
|
连接密封试验 偏角试验a 负压试验a |
无破裂,无渗漏 无破裂,无渗漏 无破裂,无渗漏 |
见 7.11.1 见 7.11.2 见7. 11.3 |
| a 仅适用于弹性密封圈连接方式。 | ||
6.8卫生性能
6. 8.1输送饮用水的管材的卫生性能应符合GB/T 17219—1998。
6.8.2输送饮用水的管材的氯乙烯单体含量应不大于1.0mg/kg。